Waqf Al-Sharif Ali Libas Al-Abdali - Makkah
Rebar corrosion testing via half-cell device to verify structural integrity.

Project Snapshot
For the Waqf Al-Sharif Ali Libas Al-Abdali property in Al-Misfalah, TECHNO Soil Lab tested rebar corrosion levels inside the structural elements using a half-cell device, verifying the building's structural integrity per standard specifications.
Scope of Work
Half-Cell Testing: Measuring Rebar Corrosion Without Breaking the Concrete
Half-cell potential testing detects the likelihood of active corrosion in rebar inside a concrete element by measuring electrochemical potential on the concrete surface, without needing to break open the element or physically expose the steel. At Waqf Al-Sharif Ali Libas Al-Abdali in Al-Misfalah, this non-destructive test helped pinpoint likely corrosion areas before repair decisions were made, saving the owner the cost of unnecessary full-scale exposure and directing renovation work to the areas that actually needed it.
Project Gallery



Related Articles
Related Projects
Have a project underway?
Talk to our field team about testing and quality assurance for your build.
Start your project with us