Concrete and Cement Blocks
Testing solid or hollow units under the project classification.
Testing for cement blocks, interlock pavers, and curbstones covering dimensions, compressive strength, water absorption, and density by product specification.

“Block” is not a single product category. Units may be solid or hollow, load-bearing or non-load-bearing, while interlock pavers and curbstones have different geometry, uses, and test methods. A request should therefore identify the product, nominal size, batch, intended use, and governing specification before samples are selected.
Concrete masonry testing may include actual dimensions, relevant wall or web thicknesses, compressive strength, water absorption, and density or mass where requested. Pavers and curbs may require length, width, thickness, and geometric checks, followed by compression, flexural, or splitting tests as specified. Use-face, shape, or colour identification can be recorded when visual checks are in scope. Results are compared with the stated classification and project limits.
For Makkah (Mecca) sites, teams depart from Al-Bay'ah in Ash-Shara'i. Typical normal-day driving is about 30 minutes to Ajyad, 30 minutes to Al-Ghazzah, and 35 minutes to Ash-Shawqiyah. Sampling in Al-Hatim, Jarwal, or Al-Hijrah can be arranged after the storage point is confirmed. Ramadan and Hajj access conditions may change timing.
Separate each manufacturer, batch, product, and size into clearly marked stacks. Provide the sampling plan, specimen quantity, tests, and standard, plus safe handling for removal and transport. The report describes the tested specimens; acceptance of the whole delivery follows the contract, quality plan, and authorized project decision.
Our field teams set out from the lab in Al-Bay'ah, Ash-Shara'i, to all ten sub-municipalities of Makkah (Mecca) — 101 districts under the official names adopted by the Makkah Municipality.
Lab HQ
Ath-Thaniyah, Zamzam, Uhud, Al-Maqam, Ash-Shara'i, Al-Yamamah, At-Tarwiyah, As-Salam, Ar-Rashidiyah, Al-Kawthar, Al-Mughammis, Ma'ad, Al-Khadra, Al-Bay'ah, Al-Marwah, As-Sanabil, Al-Barakah, Taybah, Al-Fath, Al-Abidiyah, Al-Ji'ranah
Al-Aziziyah, Al-Jami'ah, Al-Mursalat, Al-Awali, An-Naseem, Al-Husayniyah, Badr, As-Safa, Tuwa, Al-Hudaybiyah
Al-Jumayzah, Al-Khansa, Ar-Rawdah, As-Sulaymaniyah, Al-Adl, Al-Ma'abidah, Jabal An-Nur, Wadi Jalil, Ri' Adhakhir
Al-Masfalah, Kudai, Ar-Rusayfah, At-Taqwa, Al-Hindawiyah, Jurhum, Al-Khalidiyah
Ajyad, Al-Hatim
Rua Al-Haram, Jarwal, Al-Hajun, Al-Biban, At-Taysir, Hunayn
An-Nawariyah, Al-Umrah, At-Tan'eem, Al-Buhayrat, Dar As-Salam, Qurtubah, Al-Hamra, Umm Al-Jud, Ash-Shumaysi, Al-Usaylah, Al-Aqabah, Ar-Rawabi
Al-Andalus, Al-Utaybiyah, Ash-Shuhada, Az-Zahra, An-Nuzhah, Ad-Diyafah, Az-Zahir, As-Salamah
Haret Al-Bab (New), Ash-Shubaykah (New), Ash-Shamiyah (New), Shi'b Amir (New), Shi'b Ali (New), Al-Judariyah (New), Al-Hajlah (New), Al-Misyal (New), As-Suq As-Saghir (New), Al-Qashashiyah (New), Al-Ghazzah (New), Al-Qararah (New), Al-Mudda'a (New), Al-Falaq (New), An-Naqa (New)
Al-Hijrah, Ash-Shawqiyah, Al-Kakiyah, Al-Ukayshiyah, King Fahd, As-Safwah, Al-Muhammadiyah, Al-Furqan, Al-Basatin, As-Safrah, Batha Quraysh
Estimated driving times from the lab on normal days; they can be longer during Ramadan and the Hajj season.
In Short
Block, interlock-paver, and curbstone testing measures properties of submitted product samples, such as dimensions, compressive strength, water absorption, and density where requested. The service starts by identifying the unit, intended use, governing specification, and sampling plan; results are then compared with the project-supplied limits rather than one value for every product.
Block products differ by material, configuration, and use: solid or hollow, load-bearing or non-load-bearing, insulating or lightweight, plus paving units and curbstones. A request saying only “block” is incomplete. Product type, size, intended use, batch, and specification are needed for the correct test and comparison.
Testing a delivered batch provides evidence about the tested samples. Result reliability begins with a sampling plan representing the batch, protected transport, and clear specimen identification. The laboratory records results against supplied requirements; acceptance of the entire delivery follows the quality plan, contract, and authorized project decision.
Unit type and intended use define the test; blocks, pavers, and curbstones are not treated as one product.
Testing solid or hollow units under the project classification.
Tests for paving or edging units according to product form and specification.
The required standard and edition are confirmed in the work order before comparison or conformity evaluation.
Sampling, dimensions, compression, absorption, and density for specified concrete units
Specification for load-bearing concrete masonry units where adopted
Specification for non-load-bearing concrete masonry units where adopted
Specification for solid concrete interlocking paving units
Product limits, classification, and tolerances stated in the contract or named Saudi specification
A usable result needs representative samples and a defined request, not unidentified units.
1. Define Product and Requirement
We collect product type, use, nominal size, manufacturer or batch data, standard, and acceptance limits.
2. Sample and Identify
Samples are selected under the project plan or received with source, quantity, condition, and visible damage recorded.
3. Measure and Test
Dimensions and specified strength or absorption tests are performed, recording specimen preparation and result calculations.
4. Report and Compare
The report lists each specimen result and the project-supplied requirement, flagging deviations for authorized review.
7 field and laboratory tests available by project scope
Compressive Strength
مقاومة إجهاد الكسر
Unit: sample
Water Absorption
نسبة الامتصاص
Unit: sample
Dimensions
الأبعاد
Unit: sample
Fire Resistance (blocks)
مقاومة الحريق (بلوك)
Unit: sample
Flexural Strength (where required by product standard)
مقاومة الانحناء (عند طلبها حسب مواصفة المنتج)
Unit: sample
Splitting Tensile Strength (where required)
مقاومة الشد الانشطاري (عند طلبها)
Unit: test
Density
الكثافة
Unit: sample
Field and laboratory tests selected to match the project scope
Accumulated technical experience in testing & engineering consultancy
Head office in Makkah, with equipped field teams in all five cities
Test selection by project type, the pre-contract checklist, what drives the quote and what the report contains — on the main service page.
Read the full guideOn normal days, typical driving is about 30 minutes to Ajyad or Al-Ghazzah and 35 minutes to Ash-Shawqiyah from Al-Bay'ah. Ramadan and Hajj may change timing, while sampling speed depends on marked stacks and safe handling.
Explore the rest of our accredited engineering tests in one place

Soil
A soil testing laboratory covering pre-construction boreholes, in-situ testing, sampling, laboratory analysis, and geotechnical reporting according to each project's scope.

Concrete
Fresh and hardened concrete testing covering slump, temperature, specimens, compressive strength, concrete cores, and non-destructive methods to project specifications.

Asphalt
Asphalt mixture and pavement testing covering Marshall, binder content, gradation, Gmm, cores, thickness, density, and compaction to project specifications.

Aggregate
Fine and coarse aggregate testing for gradation, relative density, absorption, bulk density, abrasion, and soundness by intended use and project specification.

Rebar
Rebar batch testing covering yield, tensile strength, elongation, bend, mass per metre, and chemical composition under the specified grade and project standard.

Chemical
Book a water or soil sample and get results within days — turbidity, total hardness, calcium, magnesium, pH, sulfates and chlorides, for drinking, irrigation, sewage, well, hotel and farm water.
Our specialized team is ready to mobilize to your site anywhere in the Kingdom.